36b6d7f84b6ff7d49ac9 · A superconductor-insulator-normal metal bolometer with microwave readout suitable for large-format arrays
A superconductor-insulator-normal metal bolometer with microwave readout suitable for large-format arrays
We demonstrate high bandwidth and low noise readout of a superconductor-insulator-normal metal-insulator-superconductor hot-electron bolometer element. We measure a noise equivalent temperature of better than .06 'K/Hz' and infer an electrical noise
{
"title_en": "A superconductor-insulator-normal metal bolometer with microwave readout suitable for large-format arrays",
"designation": "",
"series": "",
"status": "",
"date": "2005-01-28",
"date_original": "January 28, 2005",
"url": "https://www.nist.gov/publications/superconductor-insulator-normal-metal-bolometer-microwave-readout-suitable-large-1",
"source": "NIST Publications",
"display_en": "",
"authors_en": "D. R. Schmidt, Anna Clark , William Duncan , Kent D. Irwin , Nathan A. Tomlin , Joel Ullom , Konrad Lehnert",
"abstract_excerpt_en": "We demonstrate high bandwidth and low noise readout of a superconductor-insulator-normal metal-insulator-superconductor hot-electron bolometer element. We measure a noise equivalent temperature of better than .06 'K/Hz' and infer an electrical noise",
"id": "36b6d7f84b6ff7d49ac9",
"sources": [
"NIST Publications"
],
"source_records": [
{
"title_en": "A superconductor-insulator-normal metal bolometer with microwave readout suitable for large-format arrays",
"designation": "",
"series": "",
"status": "",
"date": "2005-01-28",
"date_original": "January 28, 2005",
"url": "https://www.nist.gov/publications/superconductor-insulator-normal-metal-bolometer-microwave-readout-suitable-large-1",
"source": "NIST Publications",
"display_en": "",
"authors_en": "D. R. Schmidt, Anna Clark , William Duncan , Kent D. Irwin , Nathan A. Tomlin , Joel Ullom , Konrad Lehnert",
"abstract_excerpt_en": "We demonstrate high bandwidth and low noise readout of a superconductor-insulator-normal metal-insulator-superconductor hot-electron bolometer element. We measure a noise equivalent temperature of better than .06 'K/Hz' and infer an electrical noise"
}
],