52b9b490b4377bed05df · Effects of Using an Unshielded Cable as a Reference Standard in Cable Shielding Measurements, or, Do You Really Want to Base Your Results on a Naked Cable?
Effects of Using an Unshielded Cable as a Reference Standard in Cable Shielding Measurements, or, Do You Really Want to Base Your Results on a Naked Cable?
We examine the effects of using an unshielded cable as a reference standard for the evaluation of the high-frequency shielding effectiveness of cables. We placed an unshielded cable (wire) in five different configurations in our reverberation chamber. In
{
"title_en": "Effects of Using an Unshielded Cable as a Reference Standard in Cable Shielding Measurements, or, Do You Really Want to Base Your Results on a Naked Cable?",
"designation": "",
"series": "",
"status": "",
"date": "2006-08-01",
"date_original": "August 1, 2006",
"url": "https://www.nist.gov/publications/effects-using-unshielded-cable-reference-standard-cable-shielding-measurements-or-do",
"source": "NIST Publications",
"display_en": "",
"authors_en": "Jason B. Coder , John M. Ladbury",
"abstract_excerpt_en": "We examine the effects of using an unshielded cable as a reference standard for the evaluation of the high-frequency shielding effectiveness of cables. We placed an unshielded cable (wire) in five different configurations in our reverberation chamber. In",
"id": "52b9b490b4377bed05df",
"sources": [
"NIST Publications"
],
"source_records": [
{
"title_en": "Effects of Using an Unshielded Cable as a Reference Standard in Cable Shielding Measurements, or, Do You Really Want to Base Your Results on a Naked Cable?",
"designation": "",
"series": "",
"status": "",
"date": "2006-08-01",
"date_original": "August 1, 2006",
"url": "https://www.nist.gov/publications/effects-using-unshielded-cable-reference-standard-cable-shielding-measurements-or-do",
"source": "NIST Publications",
"display_en": "",
"authors_en": "Jason B. Coder , John M. Ladbury",
"abstract_excerpt_en": "We examine the effects of using an unshielded cable as a reference standard for the evaluation of the high-frequency shielding effectiveness of cables. We placed an unshielded cable (wire) in five different configurations in our reverberation chamber. In"
}
],
"translation_state": "none"
}